Today, Wuxi Xinming automatic control valve industry Co., Ltd. will introduce the inspection method of pneumatic actuator for you (below): Then explain the inspection method of pneumatic actuator in the previous period 8. Sensitivity test: add and reduce air pressure at the stroke of signal pressure 0.03, 0.06 and 0.09mpa respectively, and test the required signal pressure change value when the cylinder piston rod starts to move 0.1mm, with the upper limit of change being ≤ 0.2; 9. Sealing test of piston cylinder: Connect a pressure of 0.5 mpa to any air chamber of the cylinder, and then cut off the air source. Within 10 minutes, the pressure drop in the cylinder should not exceed 0.01mpa; 10. Electrical zero point detection of azimuth transmitter: open the azimuth cover and connect the wire; Input 12ma current signal (0.06 mpa), and adjust the circular eccentric wheel in the transmitter at this time to align the black line on the circular eccentric wheel with the white line on the circuit board; Then input 4ma current (0.02 mpa), and at this moment can adjust the zero potentiometer in the transmitter to make the output current 4ma; Electrical zero error should be ≤ 1%; 11. Electrical full-scale detection of azimuth transmitter: input 20ma current signal (0.1 mpa), and adjust the range potentiometer in the transmitter to make the output current 20ma at this moment; Electrical full-scale error should be ≤ 1%; 12. Full stroke error calibration of azimuth response current: input 4ma current (0%), and then gradually add input signal 8ma current (25%), 12ma current (50%), 16ma current (75%), 20ma current (100). Considering the nonlinear error of viewpoint change converted from linear displacement, 0%, 50%, 100 point response current errors should be ≤ 1%,25%, 75% point response current error should be ≤ 2%; 13, azimuth reaction current positive and negative stroke variation test: the same as the cylinder positive piston reverse stroke variation test method, the actual positive and negative azimuth reaction current-stroke connection, the same reaction current value of the cylinder piston positive and negative stroke value difference upper limit to 1%; 14, make good verification records, according to the contents of the verification record form item by item carefully fill in, inspection personnel need to sign; 15. After passing the above tests, the connection terminals in the azimuth transmitter shall be plugged in, the back cover shall be tightened, and then the air source inlet of the valve positioner shall be plugged with a plug. The above is all the contents of the inspection method for pneumatic actuators specifically introduced by Wuxi Xinming automatic control valve industry co., ltd. if you have any questions about pneumatic actuators, please call us at any time and wait for your cooperation.

Inspection Methods for Pneumatic Actuators (Part II)

Today, Wuxi Xinming automatic control valve industry Co., Ltd. will give you a specific introduction.Pneumatic actuatorInspection method (below):

气动执行器
Then the previous explanationPneumatic actuatorThe inspection method
8. Sensitivity test: add and reduce air pressure at the stroke of signal pressure 0.03, 0.06 and 0.09mpa respectively, and test the required signal pressure change value when the cylinder piston rod starts to move 0.1mm, with the upper limit of change being ≤ 0.2;
9. Sealing test of piston cylinder: Connect a pressure of 0.5 mpa to any air chamber of the cylinder, and then cut off the air source. Within 10 minutes, the pressure drop in the cylinder should not exceed 0.01mpa;
10. Electrical zero point detection of azimuth transmitter: open the azimuth cover and connect the wire; Input 12ma current signal (0.06 mpa), and adjust the circular eccentric wheel in the transmitter at this time to align the black line on the circular eccentric wheel with the white line on the circuit board; Then input 4ma current (0.02 mpa), and at this moment can adjust the zero potentiometer in the transmitter to make the output current 4ma; Electrical zero error should be ≤ 1%;
11. Electrical full-scale detection of azimuth transmitter: input 20ma current signal (0.1 mpa), and adjust the range potentiometer in the transmitter to make the output current 20ma at this moment; Electrical full-scale error should be ≤ 1%;
12. Full stroke error calibration of azimuth response current: input 4ma current (0%), and then gradually add input signal 8ma current (25%), 12ma current (50%), 16ma current (75%), 20ma current (100). Considering the nonlinear error of viewpoint change converted from linear displacement, 0%, 50%, 100 point response current errors should be ≤ 1%,25%, 75% point response current error should be ≤ 2%;
13, azimuth reaction current positive and negative stroke variation test: the same as the cylinder positive piston reverse stroke variation test method, the actual positive and negative azimuth reaction current-stroke connection, the same reaction current value of the cylinder piston positive and negative stroke value difference upper limit to 1%;
14, make good verification records, according to the contents of the verification record form item by item carefully fill in, inspection personnel need to sign;
15. After passing the above tests, the connection terminals in the azimuth transmitter shall be plugged in, the back cover shall be tightened, and then the air source inlet of the valve positioner shall be plugged with a plug.








气动执行器
The above is all the contents of the inspection method for pneumatic actuators specifically introduced by Wuxi Xinming automatic control valve industry co., ltd. if you have any questions about pneumatic actuators, please call us at any time and wait for your cooperation.